TECHNICAL
TOLERANCE TABLE
Tolerances used on DMC products are from DIN Standarts. All tolerances that used are listed below according to their category. Even the tolerance interval allows, all DMC products’s tolerances are produced with the possible least diversion degrees and extreme accurancy.
External Diameter ( + ) | ||||
k5 | k6 | m6 | r6 | |
Ø10 – Ø18 | +9 + 1 | + 12 + 1 | + 18 +7 | +34 +23 |
Ø18 – Ø30 | + 11 +2 | + 15 +2 | +21 +8 | +41 +28 |
Ø30 – Ø50 | + 13 +2 | + 18 +2 | +25 +9 | +50 +34 |
Ø50 – Ø65 | + 15 | +21 | +30 | +60 +41 |
Ø65 – Ø80 | +2 | +2 | + 11 | +62 +43 |
Ø80 – Ø100 | + 18 | +25 | +35 | +73 +51 |
Ø100 – Ø120 | +3 | +3 | + 13 | +76 +54 |
Ø120-Ø140 | +21 +3 | +28 +3 | +40 + 15 | +88 +63 |
Internal Diameter ( + ) | ||||||
C9 | F7 | G7 | G6 | H7 | H4 | |
Ø10-Ø18 | + 138 +95 | +34 + 16 | +24 +6 | + 17 +6 | + 18 0 | +5 0 |
Ø18 – Ø30 | + 162 + 110 | +41 +20 | +28 7 | +20 +7 | +21 0 | +6 0 |
Ø30 – Ø40 | + 182 + 120 | +50 | +34 | +25 | +25 | +7 |
Ø40 – Ø50 | + 192 + 130 | +25 | +9 | +9 | 0 | 0 |
Ø50 – Ø65 | +214 + 140 | +60 | +40 | +29 | +30 | +8 |
Ø65 – Ø80 | +224 + 150 | +30 | + 10 | + 10 | 0 | 0 |
Ø80-Ø100 | +257 + 170 | +71 | +47 | +34 | +35 | + 10 |
Ø100-Ø120 | +267 + 180 | +36 | + 12 | + 12 | 0 | 0 |
External Diameter ( – ) | |||||||
e7 | f7 | f6 | g6 | h6 | h5 | h3 | |
Ø6-Ø10 | -25 | -13 | -13 | -5 | 0 | 0 | 0 |
-40 | -28 | -22 | -14 | -9 | -6 | -2,5 | |
Ø10-Ø18 | -32 | -16 | -16 | -6 | 0 | 0 | 0 |
-50 | -34 | -27 | -17 | -11 | -8 | -3 | |
Ø18 – Ø30 | -40 | -20 | -20 | -7 | 0 | 0 | 0 |
-61 | -41 | -33 | -20 | -13 | -9 | -4 | |
Ø30 – Ø50 | -50 | -25 | -25 | -9 | 0 | 0 | 0 |
-75 | -50 | -41 | -25 | -16 | -11 | -4 | |
Ø50 – Ø80 | -60 | -30 | -30 | -10 | 0 | 0 | 0 |
-90 | -60 | -49 | -29 | -19 | -13 | -5 | |
Ø80 – Ø120 | -72 | -36 | -36 | -12 | 0 | 0 | 0 |
-107 | -71 | -58 | -34 | -22 | -15 | -6 |